927 resultados para Anterior compartment


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the study was to compare the efficacy and safety of transvaginal trocar-guided polypropylene mesh insertion with traditional colporrhaphy for treatment of anterior vaginal wall prolapse.This is a randomized controlled trial in which women with advanced anterior vaginal wall prolapse, at least stage II with Ba a parts per thousand yenaEuro parts per thousand+1 cm according to the Pelvic Organ Prolapse Quantification (POP-Q) classification, were randomly assigned to have either anterior colporrhaphy (n = 39) or repair using trocar-guided transvaginal mesh (n = 40). the primary outcome was objective cure rate of the anterior compartment (point Ba) assessed at the 12-month follow-up visit, with stages 0 and I defined as anatomical success. Secondary outcomes included quantification of other vaginal compartments (POP-Q points), comparison of quality of life by the prolapse quality of life (P-QOL) questionnaire, and complication rate between the groups after 1 year. Study power was fixed as 80 % with 5 % cutoff point (p < 0.05) for statistical significance.The groups were similar regarding demographic and clinical preoperative parameters. Anatomical success rates for colporrhaphy and repair with mesh placement groups were 56.4 vs 82.5 % (95 % confidence interval 0.068-0.54), respectively, and the difference between the groups was statistically significant (p = 0.018). Similar total complication rates were observed in both groups, with tape exposure observed in 5 % of the patients. There was a significant improvement in all P-QOL domains as a result of both procedures (p < 0.001), but they were not distinct between groups (p > 0.05).Trocar-guided transvaginal synthetic mesh for advanced anterior POP repair is associated with a higher anatomical success rate for the anterior compartment compared with traditional colporrhaphy. Quality of life equally improved after both techniques. However, the trial failed to detect differences in P-QOL scores and complication rates between the groups.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El prolapso del piso pélvico es una entidad frecuente, especialmente en pacientes postmenopáusicas y en su gran mayoría requiere tratamiento quirúrgico. En este estudio comparamos la aparición de complicaciones postoperatorias tempranas entre la colporrafia anterior con técnica clásica (TC) versus la colporrafia anterior con técnica de sitio especifico (CSE). Se realizó un estudio observacional analítico, retrospectivo, de dos cohortes de pacientes que requirieron colporrafia anterior entre agosto de 2009 hasta junio de 2012. Las características de cada grupo fueron homogéneas y comparables. El desenlace de mayor frecuencia fue dehiscencia de la línea de sutura, sin embargo, no se encontraron diferencias estadísticamente significativas entre las dos técnicas. La aparición de reprolapso temprano y el diagnóstico de abscesos o hematomas presentaron frecuencias que carecen de diferencia significativa. No hubo complicaciones tempranas graves tales como sangrado intraoperatoria mayor o lesiones vesicouretrales. Los resultados sugieren que las dos técnicas tienen una incidencia baja de complicaciones postoperatorias tempranas y por lo tanto parecen ser seguros dentro del manejo quirúrgico del prolapso del componente anterior del piso pélvico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A partial genomic clone of Bombyx mori homologue of the segment polarity gene Cubitus interruptus (BmCi), encoding the conserved zinc finger domain and harbouring two introns, has been characterized. BmCi was expressed in the silkglands of B. mori from embryonic to the late larval stages(3rd, 4th and 5th intermoults). The expression was confined to the anterior region of the middle silkglands, overlapping with the domain of sericin-2 expression and excluding the domains of Bm invected expression, namely the middle and posterior regions of the middle silkglands. In the wing discs, the expression was restricted to the anterior compartment, which increased from 4th to 5th larval intermoults and declined later in the pupal wing buds. In gonadal tissues (both ovaries and testes) BmCi was expressed from the larval to pupal stages. The transcripts were localized to the sperm tubes containing spermatogonia in the testis of Bombyx larvae. BmCi expression, however, was not detected in any of these tissues during the moulting stages. Expression of Ci in the wing discs and gonads is evolutionarily conserved, while the silkgland represents a novel domain. Our results imply that BmCi is involved in the specification and maintenance of micro-compartment identity within the middle silkglands.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tendon stiffness may be involved in limiting peak musculoskeletal forces and thus may constitute an upper limit for bone strength. The patellar tendon bone (PTB) graft, which is harvested from the patellar tendon during surgical reconstruction of the anterior cruciate ligament (ACL), is an ideal scenario to test this hypothesis. Eleven participants were recruited who had undergone surgical reconstruction of the ACL with a PTB graft 1-10 years prior to study inclusion. As previously reported, there was no side-to-side difference in thigh muscle cross-sectional area, in maximum voluntary knee extension torque, or in patellar tendon stiffness, suggesting full recovery of musculature and tendon. However, in the present study bone mineral content (BMC), assessed by peripheral quantitative computed tomography, was lower on the operated side than on the control side in four regions studied (P = 0·0019). Differences were less pronounced in the two sites directly affected by the operation (patella and tibia epiphysis) when compared to the more remote sites. Moreover, significant side-to-side differences were found in BMC in the trabecular compartment in the femoral and tibial epiphysis (P = 0·004 and P = 0·047, respectively) with reductions on the operated side, but increased in the patella (P = 0·00016). Cortical BMC, by contrast, was lower on the operated side at all sites except the tibia epiphysis (P = 0·09). These findings suggest that impaired recovery of BMC following ACL reconstruction is not because of lack of recovery of knee extensor strength or patellar tendon stiffness. The responsible mechanisms still remain to be determined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extension of the vertebrate body results from the concerted activity of many signals in the posterior embryonic end. Among them, Wnt3a has been shown to play relevant roles in the regulation of axial progenitor activity, mesoderm formation and somitogenesis. However, its impact on axial growth remains to be fully understood. Using a transgenic approach in the mouse, we found that the effect of Wnt3a signaling varies depending on the target tissue. High levels of Wnt3a in the epiblast prevented formation of neural tissues, but did not impair axial progenitors from producing different mesodermal lineages. These mesodermal tissues maintained a remarkable degree of organization, even within a severely malformed embryo. However, from the cells that failed to take a neural fate, only those that left the epithelial layer of the epiblast activated a mesodermal program. The remaining tissue accumulated as a folded epithelium that kept some epiblast-like characteristics. Together with previously published observations, our results suggest a dose-dependent role for Wnt3a in regulating the balance between renewal and selection of differentiation fates of axial progenitors in the epiblast. In the paraxial mesoderm, appropriate regulation of Wnt/β-catenin signaling was required not only for somitogenesis, but also for providing proper anterior-posterior polarity to the somites. Both processes seem to rely on mechanisms with different requirements for feedback modulation of Wnt/β-catenin signaling, once segmentation occurred in the presence of high levels of Wnt3a in the presomitic mesoderm, but not after permanent expression of a constitutively active form of β-catenin. Together, our findings suggest that Wnt3a/β-catenin signaling plays sequential roles during posterior extension, which are strongly dependent on the target tissue. This provides an additional example of how much the functional output of signaling systems depends on the competence of the responding cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prospective, consecutive series of 106 patients receiving endoscopic anterior scoliosis correction. The aim was to analyse changes in radiographic parameters and rib hump in the two years following surgery. Endoscopic anterior scoliosis correction is a level sparing approach, therefore it is important to assess the amount of decompensation which occurs after surgery. All patients received a single anterior rod and vertebral body screws using a standard compression technique. Cleared disc spaces were packed with either mulched femoral head allograft or rib head/iliac crest autograft. Radiographic parameters (major, instrumented, minor Cobb, T5-T12 kyphosis) and rib hump were measured at 2,6,12 and 24 months after surgery. Paired t-tests and Wilcoxon signed ranks tests were used to assess the statistical significant of changes between adjacent time intervals.----- Results: Mean loss of major curve correction from 2 to 24 months after surgery was 4 degrees. Mean loss of rib hump correction was 1.4 degrees. Mean sagittal kyphosis increased from 27 degrees at 2 months to 30.6 degrees at 24 months. Rod fractures and screw-related complications resulted in several degrees less correction than patients without complications, but overall there was no clinically significant decompensation following complications. The study concluded that there are small changes in deformity measures after endoscopic anterior scoliosis surgery, which are statistically significant but not clinically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary aims of scoliosis surgery are to halt the progression of the deformity, and to reduce its severity (cosmesis). Currently, deformity correction is measured in terms of posterior parameters (Cobb angles and rib hump), even though the cosmetic concern for most patients is anterior chest wall deformity. In this study, we propose a new measure for assessing anterior chest wall deformity and examine the correlation between rib hump and the new measure. 22 sets of CT scans were retrieved from the QUT/Mater Paediatric Spinal Research Database. The Image J software (NIH) was used to manipulate formatted CT scans into 3-dimensional anterior chest wall reconstructions. A ‘chest wall angle’ was then measured in relation to the first sacral vertebral body. The chest wall angle was found to be a reliable tool in the analysis of chest wall deformity. No correlation was found between the new measure and rib hump angle. Since rib hump has been shown to correlate with vertebral rotation on CT, this suggests that there maybe no correlation between anterior and posterior deformity measures. While most surgical procedures will adequately address the coronal imbalance & posterior rib hump elements of scoliosis, they do not reliably alter the anterior chest wall shape. This implies that anterior chest wall deformity is to a large degree an intrinsic deformity, not directly related to vertebral rotation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Anterior vertebral stapling using a nitinol staple is one such treatment. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The aims of this study were threefold; (1) to measure changes in the bending stiffness of a single motion segment following staple insertion, (2) to describe the forces that occur within the staple during spinal movement, and (3) to describe the anatomical changes that occur following staple insertion. Results suggest that staple insertion consistently decreased stiffness in all directions of motion. An explanation for the finding may be found in the outcomes of the strain gauge testing and micro-CT scan. The strain gauge testing showed that once inserted, the staple tips applied a baseline compressive force to the surrounding trabecular bone and vertebral end-plate. This finding would be consistent with the current belief that the clinical effect of the staples is via unilateral compression of the physis. Interestingly however, as each specimen progressed through the five cycles of each test, the baseline load on the staple tips gradually decreased, implying that the force at the staple tip-bone interface was decreasing. We believe that this was likely occurring as a result of structural damage to the trabecular bone and vertebral end-plate by the staple effectively causing ‘loosening’ of the staple. This hypothesis is further supported by the findings of the micro-CT scan. The pictures depict significant trabecular bone and physeal injury around the staple blades. These results suggest that the current hypothesis that stapling modulates growth through physeal compression may be incorrect, but rather the effect occurs through mechanical disruption of the vertebral growth plate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone graft is generally considered fundamental in achieving solid fusion in scoliosis correction and pseudarthrosis following instrumentation may predispose to implant failure. In endoscopic anterior-instrumented scoliosis surgery, autologous rib or iliac crest graft has been utilised traditionally but both techniques increase operative duration and cause donor site morbidity. Allograft bone and bone- morphogenetic-protein alternatives may improve fusion rates but this remains controversial. This study's objective was to compare two-year postoperative fusion rates in a series of patients who underwent endoscopic anterior instrumentation for thoracic scoliosis utilising various bone graft types. Significantly better rates of fusion occurred in endoscopic anterior instrumented scoliosis correction using femoral allograft compared to autologous rib-heads and iliac crest graft. This may be partly explained by the difficulty obtaining sufficient quantities of autologous graft. Lower fusion rates in the autologous graft group appeared to predispose to rod fracture although the clinical consequence of implant failure is uncertain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Top screw pullout occurs when the screw is under too much axial force to remain secure in the vertebral body. In vitro biomechanical pullout tests are commonly done to find the maximum fixation strength of anterior vertebral body screws. Typically, pullout tests are done instantaneously where the screw is inserted and then pulled out immediately after insertion. However, bone is a viscoelastic material so it shows a time dependent stress and strain response. Because of this property, it was hypothesised that creep occurs in the vertebral trabecular bone due to the stress caused by the screw. The objective of this study was therefore to determine whether the axial pullout strength of anterior vertebral body screws used for scoliosis correction surgery changes with time after insertion. This study found that there is a possible relationship between pullout strength and time; however more testing is required as the sample numbers were quite small. The design of the screw is made with the knowledge of the strength it must obtain. This is important to prevent such occurrences as top screw pullout. If the pullout strength is indeed decreased due to creep, the design of the screw may need to be changed to withstand greater forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis (AIS) is the most common form of spinal deformity in paediatrics, prevalent in approximately 2-4% of the general population. While it is a complex three-dimensional deformity, it is clinically characterised by an abnormal lateral curvature of the spine. The treatment for severe deformity is surgical correction with the use of structural implants. Anterior single rod correction employs a solid rod connected to the anterior spine via vertebral body screws. Correction is achieved by applying compression between adjacent vertebral body screws, before locking each screw onto the rod. Biomechanical complication rates have been reported as high as 20.8%, and include rod breakage, screw pull-out and loss of correction. Currently, the corrective forces applied to the spine are unknown. These forces are important variables to consider in understanding the biomechanics of scoliosis correction. The purpose of this study was to measure these forces intra-operatively during anterior single rod AIS correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone graft is generally considered fundamental in achieving solid fusion in scoliosis correction and pseudarthrosis following instrumentation may predispose to implant failure. In thoracoscopic anterior-instrumented scoliosis surgery, autologous rib or iliac crest graft has been utilised traditionally but both techniques increase operative duration and cause donor site morbidity. Allograft bone and bone morphogenetic protein (BMP) alternatives may improve fusion rates but this remains controversial. This study's objective was to compare two-year postoperative fusion rates in a series of patients who underwent thoracoscopic anterior instrumentation for thoracic scoliosis utilising various bone graft types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Currently the treatment options for idiopathic scoliosis are observation, bracing and fusion. While brace treatment is non-invasive, and preserves the growth, motion, and function of the spine, it does not correct deformity and is only modestly successful in preventing curve progression. In adolescents who fail brace treatment, surgical treatment with an instrumented spinal fusion usually results in better deformity correction but is associated with substantially greater risk. Furthermore in younger patients requiring surgical treatment, fusion procedures are known to adversely effect the future growth of the chest and spine. Fusionless treatments have been developed to allow effective surgical treatment of patients with idiopathic scoliosis who are too young for fusion procedures. Anterior vertebral stapling is one such fusionless treatment which aims to modulate the growth of vertebra to allow correction of scoliosis whilst maintaining normal spinal motion The Mater Misericordiae Hospital in Brisbane has begun to use anterior vertebral stapling to treat patients with idiopathic scoliosis who are too young for fusion procedures. Currently the only staple approved for clinical use is manufactured by Medtronic Sofamor Danek (Memphis, TN). This thesis explains the biomechanical and anatomical changes that occur following anterior vertebral staple insertion using in vitro experiments performed on an immature bovine model. Currently there is a paucity of published information about anterior vertebral stapling so it is hoped that this project will provide information that will aid in our understanding of the clinical effects of staple insertion. The aims of this experimental study were threefold. The first phase was designed to determine the changes in the bending stiffness of the spine following staple insertion. The second phase was designed to measure the forces experienced by the staple during spinal movements. The third and final phase of testing was designed to describe the structural changes that occur to a vertebra as a consequence of staple insertion. The first phase of testing utilised a displacement controlled testing robot to compare the change in stiffness of a single spinal motion segment following staple insertion for the three basic spinal motions of flexion-extension, lateral bending, and axial rotation. For the second phase of testing strain gauges were attached to staples and used to measure staple forces during spinal movement. In the third and final phase the staples were removed and a testing specimen underwent micro-computed tomography (CT) scanning to describe the anatomical changes that occur following staple insertion. The displacement controlled testing showed that there was a significant decrease in bending stiffness in flexion, extension, lateral bending away from the staple, and axial rotation away from the staple following staple insertion. The strain gauge measurements showed that the greatest staple forces occurred in flexion and the least in extension. In addition, a reduction in the baseline staple compressive force was seen with successive loading cycles. Micro-CT scanning demonstrated that significant damage to the vertebral body and endplate occurred as a consequence of staple insertion. The clinical implications of this study are significant. Based on the findings of this project it is likely that the clinical effect of the anterior vertebral staple evaluated in this project is a consequence of growth plate damage (also called hemiepiphysiodesis) causing a partial growth arrest of the vertebra rather than simply compression of the growth plate. The surgical creation of a unilateral growth arrest is a well established treatment used in the management of congenital scoliosis but has not previously been considered for use in idiopathic scoliosis.